Installing a standard 9-volt alkaline battery will preserve the controllers time and program
in the memory during a power outage.
CAUTION: Batteries contain hazardous material. Always handle and discard
batteries properly in accordance with the battery manufacturers recommendations.
Step 1 - Open the door to your controller cabinet and swing open the control module by
flexing the release tab to the right.
Step 2 - Open the battery compartment located at the top rear of the control module.
Step 3 - Insert a standard 9 volt battery onto the battery clip.
Step 4 - Replace the battery compartment lid and close the control module.
See Figure 1 on page 4.
CAUTION: Before connecting the
valves to the controller, make sure
that the power supply is unplugged
(indoor model) or disconnected
(outdoor model).
Step 1 - Open the door to your controller
cabinet and swing open the
control module by flexing the
release tab to the right.
Step 2 - Attach one lead from each valve
to a single common wire. Route
the common wire through the
conduit opening and secure it to
the VC (valve common) terminal
of the terminal board.
Step 3 - Route each remaining valve wire
through the provided conduit
opening located at the bottom of
the controller cabinet. Secure
each valve wire to the desired
numbered terminal. See Figure 2.
CAUTION: All wiring splices must be waterproofed to prevent short circuit and
corrosion. A grease cap or similar waterproofing method can be used to insulate
each wire splice connection.
Note: This controller is designed to work with 24 V a.c., 5VA solenoid operated valves. A
maximum of two solenoids per terminal may be used, and no more than three solenoids
should be on at any time. This includes the master valve and/or pump start, if one is being
used. Load requirements should not exceed 1.0 amp maximum current draw.
Valve Connection
MV
1
2
3
Figure 2
Plug-in
Transformer
Master Valve
or Pump Relay
Valve 1
Valve 2
Valve 3
5
Valve Common