Drip Multi-Program Automatic Timer
You have purchased a quality, multi-program automatic hose-end timer that uses an efficient solenoid snap-on/snap off valve. Please read these operating instructions carefully in order to
become familiar with the features, correct installation, and use of the timer. Verify that the timer performs as programmed when used for the first time. This timer should only be operated by
adults who are familiar with the operating instructions.
Designed Use This timer is designed for use outdoors only for the control of sprinklers and water systems. The timer is not suitable for use: 1) If your water pressure exceeds 145 psi (10 bar);
2) If you use a well, bore, or unfiltered water supply; 3) If you use any type of pump to draw water; 4) For any commercial/industrial application; and 5) In conjunction with chemicals, foodstuffs,
flammable, or explosive materials.
How the Electronic Timer Works Your automatic timer will water your garden and hanging baskets automatically according to the program you choose. You can set the timer to water your
garden early in the morning or late at night when water evaporates the least. It will continue to water while you are away. It provides two flexible methods to control irrigation:
1. Manual: Press Man/Auto button to switch between: On - Off - Auto (you will hear a click when on; off is silent).
2. Automatic: Can water up to 8 times per day. Choose quickly from 15 different day combinations to control which days of the week the timer operates.
Installing the Battery (see Figure 1)
1. Remove the timer face by pressing the release button on the underside of the timer.
2. Remove the battery cover and gasket (secured by two screws).
3. Connect a 9V battery (not included) to the battery terminals.
4. Install the battery cover and gasket. Make sure the gasket is properly aligned. Secure battery cover (two screws).
5. We recommend planning and recording your watering programs before programming the timer.
6. Set the current day and time
7. Set the desired watering programs
8. Re-install the timer face.
9. Attach the timer to the water tap. For 0.75" (20mm) – attach directly. For 1" (25mm) – remove 0.75" (20mm)
threaded bushing.
Note: Timer must only be mounted in a vertical position with the connector nut pointing vertically upwards
10. Attach the hose to threaded outlet or attach 0.710 compression fitting to connect Blue Stripe
®
Drip 1/2" (13mm)
tubing.
11. Do not use tools! Tighten connections by hand only – do not over tighten!
Programming the Timer
1. Press “Program” once. Program 1 ON appears on the display (see Figure 3).
2. Press “Hour” and “Minute” to set start time, program 1 (24hr clock; see Figure 4).
3. Press “Day” to set days of the week that program 1 operates. (defaults to Mon-Sun, i.e. every day).
4. Press “Program” again. Program 1 OFF appears on the display (see Figure 5).
5. Press “Hour” and “Minute” to set finish time, program 1 (see Figure 6).
If you only want your watering system to activate once per day, for the Days set in step 3 above,
stop here.
6. Press “Program” again. Program 2 ON appears on the display.
7. Repeat steps 2 through 5 above for a second watering program on the above days, or watering on
selected days only.
• Up to 8 programs may be set from a total of 15 different day-of-the-week configurations
• Ensure that the days for the OFF setting are the same as those for the ON setting
• Ensure that every ON time has an OFF time!!
• To exit programming press “time” which returns the display to the current time and day
If after pressing “Program” you press “Day” repeatedly the following day combinations appear (see step 3 above)
To ensure long life and prevent damage to the automatic timer
• Use with cold, main connection water only. Check the filter as necessary.
• Avoid tension or pulling on the hose leading or drip tubing from the timer.
• We recommend removing the timer from the tap during cold months, particularly where temperature drops below 41°F (5°C). The timer must not be subjected to freezing temperatures or frosts.
• Do not use the timer if it is likely to be subject to more than ‘seasonal’ amounts of water (eg. In the path of sprinklers or other emitter or with a leaking tap).
Technical Data
Power: One 9-volt alkaline battery (use a high power alkaline battery)
Battery life: 1 season (6 months) normal use.
Recommended operating temperature: 41°F – 100°F (5°C to 38°C)
Recommended water pressure: 21 PSI – 100 PSI (1.4 bar to 6.9 bar)
Maximum operating pressure: 145 PSI (10 bar). In higher pressure areas, use a pressure reducer from the tap.
© The Toro Company • www.toro.com • 800-367-8676 Part Number 373-0564 Rev. 03
Understanding the Multi-Program Automatic Timer (see Figure 2)
Control Keys
1. Time – used to set current time of day and return to clock
screen. Press and hold to set the current time and day.
2. Min – used to set minutes of current time and watering
start/finish times. Press to advance one minute.
3. Hour – used to set hour, current time, and watering
start/finish times. Press to advance one hour.
4. Day – used to set current day and watering days.
Press to advance to next day.
5. Man/Auto – used to select between manual on/off and
automatic watering mode.
6. Prog – used to set or change stored watering programs.
Note: If the timer is left in programming mode for 1 minute
without any selections made, the timer will return to
automatic mode.
7. Esc – used to clear programs in programming mode or to
set the keypad lock. To lock the keypad, hold Esc for
more than 3 seconds. Hold again for 3 seconds to
unlock the keypad.
11
12
13
14
8 9 10
1 2 3 4
5
6
7
1 MO
2 TU
3 WE
4 TH
5 FR
6 SA
7 SU
8 MO
9 TU
WE
TH
FR
SA
10
11 MO
12 TH
TU
SA SU
FR
WE
SA
10
11 MO
12
TU WE TH FR SA
MO TU WE TH FR
MO TU WE TH FR SA SU
Figure 1
Battery Cover
and Gasket
9V Battery
Timer Face
Release Tab
25mm
Fitting
20mm
Bushing
Figure 2
Figure 3
Figure 5
Figure 4
Figure 6
Functions
All functions can be selected by pressing the Man/Auto button.
8. ON – when selected, an arrow appears above ‘ON’ on the
display panel. The valve will open and watering will commence
immediately.
9. Auto – when selected, an arrow appears above ‘AUTO’ on the
display panel. The timer is in Automatic Mode and watering will
occur according to the programs set by the User.
10. OFF – when selected, an arrow appears above ‘OFF’ on the
display panel. The valve is shut off and water is prevented from
flowing from the timer. In this mode, no watering will take place.
Display Symbols
11. Day of Week – indicates the current day of the week in
Automatic Mode and watering days selected for calendar
watering program mode.
12. Batt. – low battery symbol displayed when the battery is low.
13. Display Lock (A and a) – indicates that the keypad has been
locked. Prevents changes being made to set programs, current
time, and manual activation.
14. Program – indicates program number in programming mode.